Vulnerable parts of slide valve

Oct 05, 2025

Leave a message

1. Valve plate
Due to the direct erosion of the valve plate by flue gas, there is varying degrees of wear at the pointed arc of the valve plate. Mild cases have varying depths of pockmarks and grooves around the arc of the safety hole, while severe cases can be extensively flushed, resulting in deep grooves with a width of 15-30 millimeters and a depth of 2-4 millimeters on the valve plate. Deep grooves and pockmarks on valve plates can be locally repaired by welding. If there is heavy erosion, large-area welding can be carried out, and mechanical processing can be carried out after welding. Those with severe wear and tear should be replaced twice, while those with minor wear and tear should be repaired and reused.
2. Guide rail
The guide rail of the double acting slide valve also has heavy wear, and the wear area generally surrounds the gear key. In addition to checking for gap deformation, the wear of the guide rail should also be checked. When the wear direction is around the gear key and does not affect the operation of the guide rail, it can be repaired by welding. However, repair welding is generally not used to avoid deformation of the guide rail. When severe wear and tear are found on the guide rail, it should be replaced.
3. Seat ring
The wear of the seat ring around the gear key is relatively heavy, while it is lightly twisted elsewhere. Heavy cases should be repaired by welding (the height of the weld seam should not exceed the plane of the seat ring).
4. Valve stem
The wear at the connection between the valve stem and the valve plate, as well as at the packing, is relatively heavy, and sometimes the head of the valve stem is worn off. If it is found to be ground into a deep pit, it should be repaired by welding. If the head is found to be broken, it should be cut and welded before reprocessing.

Send Inquiry
Send Inquiry